Asco Valve Store

4 Way Solenoid Valves 8345 Series

The solenoid is an electromagnetic part of a valve, comprised of a coil, coretube, core and enclosure. ASCO Redhat brand offers the worlds largest selection of 2-, 3- and 4-way solenoid valves, designed to handle the most demanding fluid control applications.
3 WAY PILOT OPERATED Quick Exhaust Solenoid Valves
Common Specifications
Solenoid Enclosures Standard Enclosures Optional Enclosures Electrical
Valves listed in this series have Red-Hat II molded epoxy solenoids. Red-Hat II valves are identified by the change letter "G" and "H" in their catalog numbers, e.g., 8345G1 or 8345H1.
Red-Hat II -- Types 1, 2, 3, 3S, 4 and 4X Combination General Purpose and Watertight Red-Hat II -- Types 3, 3S, 4, 4X, 6, 6P, 7 and 9 Combination Explosion proof and Watertight. To order, add prefix "EF" to catalog number.

Additional constructions are available. The Optional Features Section contains descriptions and ordering information for: Open Frame Solenoids · Junction Box Enclosures · Panel Mount Constructions.
Leakage:
Liquids: none;
Air: slight leakage through exhaust when energized.
Standard Voltages: 24, 120, 240, 480 volts, AC, 60 Hz (or 110, 220 volts, AC, 50 Hz)
6, 12, 24, 120, 240 volts, DC

Other voltages are available when required.

Coil: Continuous duty molded Class F.
Nominal Ambient Temperature Ranges Valve Parts in Contact with Fluids Ordering Information  
Construction:32°F to 125°F.

DC Construction: 32°F to 104°F.

Body-- Brass or 316 S.S., as listed
Seals and Disc -- Buna "N" and Nylon
Core Tube -- 305 s.s.
Core and Plug nut -- 430F s.s.
Springs -- 302 s.s.
Shading Coil -- Copper
Piston -- Nylon
Important: We must have catalog number, voltage and Hertz, operating pressure and fluid handled. Use strainers with Solenoid Valves.

 
IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only.
 

Specifications (English Units)

Standard Solenoid Enclosures
Red-Hat II - Types 1, 2, 3, 3S, 4 and 4X
Watt Rating/Class of Coil Insulation Max
Fluid Temp.
F
Pipe
Size
Orifice
Size
(ins.)
CV
Flow
Factor
Operating Pressure Differential (psi)
Brass Body1 S.S. Body2 Constr. Ref. No. Min Max. AC Max. DC
Catalog Number Catalog Number AC DC AC DC Inlet Exh. Press. Exh. Air
Inert
Gas
Water Light Oil @ 300 SSU Air
Inert
Gas
Water Light Oil @ 300 SSU
Normally Open (Open when de-energized)
8345G001 EV8345G081 1 10.1/F 11.6/F 180 104 1/4 1/16 3/32 0.09 0.09 10 150 150 150 100 100 100
Normally Closed (Closed when de-energized)
8345H003 --------- 2 10.1/F 11.6/F 180 104 1/4 1/16 3/32 0.09 0.09 10 150 -- -- 100 -- --
Notes: 1- Brass Bodies: Standard Enclosure is Red-Hat II Types 1, 2, 3, 3S, 4 and 4X.
2- 316 S.S. Bodies: Standard Solenoid Enclosure is Red-Hat II with Explosion proof and Watertight Enclosure Types 3, 3S, 4, 4X, 6 and 6P.