Leightonstone

Solenoids/Solenoid Operators

ASCO is the worldwide leader in the design and manufacture of quality of two, three and four way ASCO solenoid valves as well as ASCO Next Generation valves, ASCO Steam Valves, ASCO Combustion Valves, ASCO Posiflow Valves, ASCO Switches
Asco Steam Valves
 
 
Common Specifications
Solenoid Enclosures Standard Enclosures Optional Enclosures Electrical
Solenoids and solenoid operators listed in this series have either Red-Hat metal enclosures, or are Red-Hat II molded epoxy constructions identified by the change letter "G" in their catalog numbers, e.g., 8200G1, and are shown in red. Red-Hat -- Type 1 General Purpose
Red-Hat II -- Types 1, 2, 3, 3S, 4 and 4X Combination General Purpose and Watertight.
Red-Hat -- Types 3, 7 and 9 Combination Explosion proof and Rain tight. To order, add prefix "EF" to catalog number.
Red-Hat II -- Types 3, 3S, 4, 4X, 6, 6P, 7 and 9 Combination Explosion proof and Watertight. To order, add prefix "EF" to catalog number.
Standard Voltages: 24, 120, 240, 480 volts, AC, 60 Hz (or 110, 220 volts, AC, 50 Hz)

6, 12, 24, 120, 240 volts, DC (solenoid operators only)

Other voltages are available when required.

Coil: Continuous duty molded Class F.
Nominal Ambient Temperature Ranges Valve Parts in Contact with Fluids Ordering Information  
AC Construction: 32°F to 125°F.

DC Construction (solenoid operators only): 32°F to 104°F.
Core Tube -- 305 s.s.
Core and Plug nut -- 430F s.s.
Seal -- Buna "N"
Shading Coil -- Copper

Additional Solenoid Operator Parts:
Disc -- Buna "N" and Nylon (3 way upper disc)
Spring -- 302 s.s.
Important: We must have catalog number, voltage and Hertz, operating pressure and fluid handled. Use strainers with Solenoid Valves. CSA certified.
Additional constructions are available. The Optional Features Section contains descriptions and ordering information for: Open Frame Solenoids · Junction Box Enclosures · Panel Mount Constructions.
 
 
Standard Solenoid Enclosures Red-Hat - Type 1 Red-Hat II - Types 1, 2, 3, 3S, 4 and 4X Orifice Size (ins.) Cv Flow Factor 4 Operating Pressure Differential (psi) Max. Fluid Temp.(°F) Watt Rating/
Class of Coil
Insulation 6
Optional Inserted Seat
Catalog
Number
Const.
Ref.
No.
Max. AC Max. DC AC DC AC DC
Air-
Inert
Gas
Water Lt. Oil
@ 300
SSU 5
Air-
Inert
Gas
Water Lt. Oil
@ 300
SSU 5
2 Way Solenoid Operators ¹, Normally Closed (closed when de-energized)
8200G1 4 ³/64 0.06 750 600 400 325 225 300 180 120 6.1/F 10.6/F 096-429-4 ²
8200G1 4 ³/32 0.17 275 200 130 110 100 100 180 120 6.1/F 10.6/F 180-222-5D ³
8200G1 4 ¹/8 0.35 135 115 90 50 50 50 180 120 6.1/F 10.6/F 180-222-1D ³
3 Way Solenoid Operators ¹, Normally Closed (closed when de-energized)
8329G1 5 ³/64 0.04 230 230 230 120 140 125 200 150 10.1/F 11.6/F 096-429-4 ²
8329G2 5 ³/64 0.06 750 600 400 325 225 300 180 120 10.1/F 11.6/F 096-429-4 ²
8329G3 5 ³/64 0.06 750 600 400 325 225 300 180 120 10.1/F 11.6/F 180-222-1D ³
3 Way Solenoid Operators ¹, Normally Open (open when de-energized)
8329G7 5 ³/64 0.04 300 300 200 200 300 120 200 150 10.1/F 11.6/F 096-429-4 ²
8329G8 5 ³/32 0.15 175 175 175 70 90 45 200 150 10.1/F 11.6/F 096-429-3 ²
8329G9 5 ¹/8 0.25 90 90 90 40 40 25 200 150 10.1/F 11.6/F 180-222-1D ³
  1. Larger operators, orifice sized and higher pressure ratings are available. Contact Leighton Stone Corporation for more information.
  2. Inserted seat has ¼-32 thread for threading into cavity.
  3. Inserted seat has ³/8-32 thread for threading into cavity.
  4. Cv will depend upon size and location of connecting passages.
  5. Maximum viscosity for 3 way solenoid opearator is 45 SSU.
  6. On 50 Hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.